HiveNightmare / SeriousSAM: world-readable SAM hive
An over-permissive ACL let the low-privilege Users group read the SAM, SYSTEM, and SECURITY registry hives, so any standard user could copy them from a shadow copy and dump the local Administrator password hash.
- Product
- Microsoft Windows (Security Accounts Manager / registry hive files)
- Vendor
- Microsoft
- Affected
- Windows 10 1809, 1909, 2004, 20H2, 21H1 (and Windows 11 pre-release) prior to the August 2021 cumulative update
- Fixed in
- August 10, 2021 cumulative update (e.g. KB5005033 for Windows 10 21H1, OS Build 19043.1165). Patch alone is insufficient: pre-existing Volume Shadow Copies must also be deleted.
- Weakness
- CWE-732
- CVSS vector
- CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Published
- 22 Jul 2021
Classified as
References
Related CVEs
- CVE-2025-33073high 8.82025
Windows SMB marshalled-target reflection
An SMB target name can hide marshalled metadata that LSASS later strips, turning an attacker-routed hostname into a local target identity and reviving same-host authentication reflection when SMB signing is not enforced.
- CVE-2022-26923high 8.82022
Certifried: AD CS certificate SAN spoofed from a writable dNSHostName
A certificate template that builds its Subject Alternative Name from the enrollee's dNSHostName lets a low-privileged user mint an authentication certificate for any machine, because dNSHostName is self-writable and not unique.
- CVE-2021-42278high 7.52021
noPac: sAMAccountName spoofing to domain controller impersonation
A standard user can rename a machine account to a domain controller's name without the trailing $, because the directory never enforces the machine-account suffix, which a Kerberos S4U2self lookup then resolves back to the real DC.
- CVE-2021-34527high 8.82021
Windows Print Spooler RpcAddPrinterDriverEx privilege escalation to RCE (PrintNightmare)
PrintNightmare (CVE-2021-34527): an authenticated low-privileged user calls RpcAddPrinterDriverEx and points a driver file at an attacker SMB share, so the SYSTEM Print Spooler loads the attacker DLL. The famous incomplete-fix saga, CVE-2021-1675 was patched first as a low-severity local escalation, but the fix was bypassable, so this RCE followed and still needed Point and Print mitigations. The PoC was published accidentally (released believing 1675 was fully patched, before 34527 was understood as a separate unpatched RCE), forcing an emergency response. The spooler runs as SYSTEM and is enabled by default, including on domain controllers.