Hexret
CVE-2020-1048high 7.8PoC available

PrintDemon: Print Spooler privileged file write

The spooler accepts an arbitrary file path as a port through a server-side API that omitted validation, then processes a persisted job after restart without the submitting user's impersonation token.

Product
Microsoft Windows Print Spooler
Vendor
Microsoft
Affected
Windows 7, Windows 8.1, Windows 10, and supported Windows Server releases before the May 2020 security updates
Fixed in
Applicable May 2020 Windows security update
Weakness
CWE-669
CVSS vector
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Published
21 May 2020

Practice this CVE, free

Classified as

References

Related CVEs

  • CVE-2025-33073high 8.82025

    Windows SMB marshalled-target reflection

    Microsoft Windows SMB client · CWE-284

    An SMB target name can hide marshalled metadata that LSASS later strips, turning an attacker-routed hostname into a local target identity and reviving same-host authentication reflection when SMB signing is not enforced.

  • CVE-2024-38077critical 9.82024

    MadLicense: base-24 license-key heap overflow

    Windows Remote Desktop Licensing Service · CWE-122

    The licensing RPC decoder allocates 21 bytes for an expected 35-character base-24 value but converts a null-terminated, attacker-controlled string of unbounded length into that buffer.

  • CVE-2021-38647critical 9.82021

    OMIGOD: OMI unauthenticated RCE via missing auth check

    Microsoft Open Management Infrastructure (OMI) · CWE-287

    An HTTP request that omits the Authorization header is dispatched without ever confirming it was authenticated, so an unauthenticated attacker runs commands as root on the OMI management agent.

  • CVE-2021-34527high 8.82021

    Windows Print Spooler RpcAddPrinterDriverEx privilege escalation to RCE (PrintNightmare)

    Microsoft Windows Print Spooler (spoolsv, MS-RPRN / MS-PAR) · CWE-269

    PrintNightmare (CVE-2021-34527): an authenticated low-privileged user calls RpcAddPrinterDriverEx and points a driver file at an attacker SMB share, so the SYSTEM Print Spooler loads the attacker DLL. The famous incomplete-fix saga, CVE-2021-1675 was patched first as a low-severity local escalation, but the fix was bypassable, so this RCE followed and still needed Point and Print mitigations. The PoC was published accidentally (released believing 1675 was fully patched, before 34527 was understood as a separate unpatched RCE), forcing an emergency response. The spooler runs as SYSTEM and is enabled by default, including on domain controllers.